<Error>
<ErrorNumber>15362</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: STEP : axis 1 AWAY limit switch is active
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800_Proofing</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<OperatorAction>
<DescriptionText><text>
First select the RESUME button from the workstation dialog box.  If
this does not correct the problem, then select RESET TRENDSETTER
from the workstation TRENDSETTER pull-down menu. If the problem persists,
call Creo Service.
</text></DescriptionText>
</OperatorAction>
<ServiceInformation>
<DescriptionText><text>
If the procedure described in Operator Action does not correct the problem, then
the stepper controller must be re-initialized. Do this either by typing "vr
init" or "ale init", or if that does not work, by resetting the recorder.  Alert
The Proofer TTE if this error occurs.
</text></DescriptionText>
</ServiceInformation>
<Cause>
This error occurs when the stepper motor HOME switch becomes active before the
stepper motor has finished moving.  Likely a hardware problem, as the away limit
is not used for the proofer.
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:04 2008 PST
</Updated>
<Links>
</Links>
</Error>